Comprehensive reconstruction of Uus St 4 apartment building via design-build contract with EIS subsidy (repeat) AI

TEDAS your procurement assistant

Ask a question about this procurement

t

Object of the procurement

  • Object: Comprehensive reconstruction of Uus St 4 apartment building (design-build contract with EIS subsidy).
  • Technical requirements:
    • Energy efficiency class C (ETA ≤150 kWh/(m²*a)).
    • Durability of building envelopes and load-bearing structures after reconstruction at least 50 years, technical systems 25 years.
    • Required insulation parameters: roof U≤0.12; external walls U≤0.20; windows U≤1.10 W/(m²·K).
    • Ventilation: supply and exhaust system with heat recovery (heat recovery ≥70%).
    • Removal…
       